Oxygen Sensor

OEM Manufacturer of a wide range of products which include oxygen sensor ao2 and mox1 medicel sensor.
  • Oxygen Sensor Ao2
  • Oxygen Sensor Ao2
  • Oxygen Sensor Ao2
  • Oxygen Sensor Ao2
Oxygen Sensor Ao2

Oxygen Sensor Ao2

Rs 2,500  / PieceGet Best Price
Target gasesOxygen
Measuring Range0-100% O2
Operating Voltage9 - 13 mV in Air
BrandHoneywell
Usage/ ApplicationVehicle Exhaust Analysis
Response Time<5 s
Expected Operating Life12 Months

CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.

When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is

fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.

Mechanical Installation

When installing the sensor, it must only be screwed in hand-tight and a gas tight seal ensured. Spanners and similar mechanical aids may not be used, as excessive force may damage the sensor thread.

Cross Sensitivity Table

Whilst CiTiceLs are designed to be highly specific to the gas they are intended to measure, they will still respond to some degree to various other gases. The table below is not exclusive and other gases not included in the table may still cause a sensor to react.

The AO2 has been tested with a number of gases which may be present in automotive exhaust to establish their level of cross interference.

 

 

Technical Specifications
MEASUREMENT
Operating Principle Partial Pressure Electrochemical
Measurement Range 0-100% O2
Output* 9 – 13 mV in Air
Response Time (T90)* <5 s
Response Time (T 99.5) <40 s
Baseline Offset* <20 mV
Linearity Linear 0-100% O2
ELECTRICAL
On Board Temperature <2% O2 equivalent
Compensation variation from 0°C to 40°C
External  Load Resitor 10 kW Minimum
Connector 3 Pin Molex header (MOLEX 22-29-2031)
Recommended Mating Part Molex 3-Way Housing (MOLEX 22-01-2035)
Molex Crimp Terminals (MOLEX 08-45-0110)
MECHANICAL
Material 40 g (nominal)
Weight Housing Red ABS
Orientation Any
Environmental
Typical Application Vehicle Exhaust Analysis
Operating Temperature Range -20°C to +50°C
Operating Pressure Range 0.5 – 2.0 Bar
Differential Pressure Range 0 to 500 mBar max
Operating Humidity Range 0 – 99% RH non-condensing
LIFETIME
Long Term Ouput Drift in 100% O2 <10% signal loss/year
Expected Operating Life 360,000% O2 hours at 20°C               286,000% O2 hours at 40°C                    or 2 years in air at STP.
Packaging Sealed blister
Specifications are valid at 20°C, 50% RH and 1013 mBar, using City Technology recommended circuitry. Performance characteristics outline the performance of sensors supplied.


Additional Information:

  • Packaging Details: Sealed blister

View Complete details

get quote request a call back
  • MOX1 MediceL Sensor
  • MOX1 MediceL Sensor
  • MOX1 MediceL Sensor
  • MOX1 MediceL Sensor
  • MOX1 MediceL Sensor
  • MOX1 MediceL Sensor
MOX1 MediceL Sensor

MOX1 MediceL Sensor

Rs 5,500  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Product Brochure

Usage/ApplicationThese sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not
Model Name/NumberMOX1
BrandCiTiceL
TypeMedical Oxygen Sensor
Type Of EquipmentMOX1
Country of OriginMade in India

CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.

When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the

sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.

Intended Use

These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.

Stabilisation Time

Allow at least 15 minutes to stabilise in the instrument before calibration or refer to manufacturers instructions.

Cleaning and Sterilisation

In case of contamination the sensor may be cleaned with distilled water and allowed to dry naturally. The sensor is not suitable for sterilisation by steam or exposure to chemicals such as ethylene oxide or hydrogen peroxide.

Calibration Interval

These sensors are designed to have minimal drift over their useful lifetime. For maximum accuracy however they should be calibrated before each use.

If the Sensor is Dropped

If a sensor is dropped, then it should be placed in quarantine for 24 hours and a follow-up check made by a 2 point calibration.

Mechanical Installation

When installing the sensor, it must only be screwed in hand-tight and a gas tight seal ensured. Spanners and similar mechanical aids may not be used, as excessive force may damage the sensor thread.

RFI/EMI Susceptibility

MediceLs contain metal and may be susceptible to RFI or EMI. They are not suitable for use in MRI environments. For further information please contact City Technology.

  Cross Sensitivity

The table below shows how MOX1 MediceLs respond when tested with the gas mixtures listed in ISO 80601-2-55.

Test Gas

% O2 Error

50% He / 50% O2

< 1%

60% N2O / 40% O2

< 1%

2% Halothane / 40% O2 / 30% N20 / 5% CO2 / Bal N2

< 1.5%

2% Enflurane / 40% O2 / 30% N20 / 5% CO2 / Bal N2

< 1.5%

2% Isoflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2

< 1.5%

Key Features and Benefits 

Meets the requirements

of ISO 80601-2-55

Linear output from

0 % to 100 % O2

13-month

warranty

RoHS compliant



Additional Information:

  • Item Code: MOX1
  • Production Capacity: 1000
  • Delivery Time: Within 1 week

View Complete details