Target gases | Oxygen |
Measuring Range | 0-100% O2 |
Operating Voltage | 9 - 13 mV in Air |
Brand | Honeywell |
Usage/ Application | Vehicle Exhaust Analysis |
Response Time | <5 s |
Expected Operating Life | 12 Months |
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is
fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
Mechanical Installation
When installing the sensor, it must only be screwed in hand-tight and a gas tight seal ensured. Spanners and similar mechanical aids may not be used, as excessive force may damage the sensor thread.
Cross Sensitivity Table
Whilst CiTiceLs are designed to be highly specific to the gas they are intended to measure, they will still respond to some degree to various other gases. The table below is not exclusive and other gases not included in the table may still cause a sensor to react.
The AO2 has been tested with a number of gases which may be present in automotive exhaust to establish their level of cross interference.
Technical Specifications | |
MEASUREMENT | |
Operating Principle | Partial Pressure Electrochemical |
Measurement Range | 0-100% O2 |
Output* | 9 – 13 mV in Air |
Response Time (T90)* | <5 s |
Response Time (T 99.5) | <40 s |
Baseline Offset* | <20 mV |
Linearity | Linear 0-100% O2 |
ELECTRICAL | |
On Board Temperature | <2% O2 equivalent |
Compensation | variation from 0°C to 40°C |
External Load Resitor | 10 kW Minimum |
Connector | 3 Pin Molex header (MOLEX 22-29-2031) |
Recommended Mating Part | Molex 3-Way Housing (MOLEX 22-01-2035) |
Molex Crimp Terminals (MOLEX 08-45-0110) | |
MECHANICAL | |
Material | 40 g (nominal) |
Weight Housing | Red ABS |
Orientation | Any |
Environmental | |
Typical Application | Vehicle Exhaust Analysis |
Operating Temperature Range | -20°C to +50°C |
Operating Pressure Range | 0.5 – 2.0 Bar |
Differential Pressure Range | 0 to 500 mBar max |
Operating Humidity Range | 0 – 99% RH non-condensing |
LIFETIME | |
Long Term Ouput Drift in 100% O2 | <10% signal loss/year |
Expected Operating Life | 360,000% O2 hours at 20°C 286,000% O2 hours at 40°C or 2 years in air at STP. |
Packaging | Sealed blister |
Specifications are valid at 20°C, 50% RH and 1013 mBar, using City Technology recommended circuitry. Performance characteristics outline the performance of sensors supplied. |
Additional Information:
View Complete details
Minimum Order Quantity: 10 Piece
Product Brochure
Usage/Application | These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not |
Model Name/Number | MOX1 |
Brand | CiTiceL |
Type | Medical Oxygen Sensor |
Type Of Equipment | MOX1 |
Country of Origin | Made in India |
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the
sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
Intended UseThese sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.
Stabilisation TimeAllow at least 15 minutes to stabilise in the instrument before calibration or refer to manufacturers instructions.
Cleaning and SterilisationIn case of contamination the sensor may be cleaned with distilled water and allowed to dry naturally. The sensor is not suitable for sterilisation by steam or exposure to chemicals such as ethylene oxide or hydrogen peroxide.
Calibration IntervalThese sensors are designed to have minimal drift over their useful lifetime. For maximum accuracy however they should be calibrated before each use.
If the Sensor is DroppedIf a sensor is dropped, then it should be placed in quarantine for 24 hours and a follow-up check made by a 2 point calibration.
Mechanical InstallationWhen installing the sensor, it must only be screwed in hand-tight and a gas tight seal ensured. Spanners and similar mechanical aids may not be used, as excessive force may damage the sensor thread.
RFI/EMI SusceptibilityMediceLs contain metal and may be susceptible to RFI or EMI. They are not suitable for use in MRI environments. For further information please contact City Technology.
Cross SensitivityThe table below shows how MOX1 MediceLs respond when tested with the gas mixtures listed in ISO 80601-2-55.
Test Gas | % O2 Error |
50% He / 50% O2 | < 1% |
60% N2O / 40% O2 | < 1% |
2% Halothane / 40% O2 / 30% N20 / 5% CO2 / Bal N2 | < 1.5% |
2% Enflurane / 40% O2 / 30% N20 / 5% CO2 / Bal N2 | < 1.5% |
2% Isoflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 | < 1.5% |
Meets the requirements of ISO 80601-2-55 | Linear output from 0 % to 100 % O2 | 13-month warranty | RoHS compliant |